Installation (for qualified installers only)

27

Rear Vent Configuration with Horizontal Termination (with vertical rise)

The termination must fall within the shaded area shown in the chart. and diffuser positions.

Up to four elbows (45° or 90° ) may be used.

Only one horizontal elbow may be used.

Use the indicated restrictor

0feet

5feet

22' (max)

20feet

15 feet

10 feet

5 feet

0 feet

0feet

5feet

10feet

15feet

Exhaust Restrictor # 5

Intake Restrictor # 2

Diffuser Position # 2

Exhaust Restrictor # 3

Intake Restrictor # 1 (stock)

Diffuser Position # 1 (stock)

10feet

15feet

20' (max)

22' (max)

20 feet

15 feet

10 feet

5 feet

0 feet

20' (max)

H2

This is considered a horizontal

elbow (it does not matter whether it turns right or left).

It may be a 90° or 45° elbow.

H1

Horizontal length is calculated by adding both lengths of horizontal run (Horizontal Length = H1 + H2).

This is considered a vertical elbow

© Travis Industries

4080214

100-01182_003

Page 27
Image 27