Installation (for qualified installers only) | 27 |
Rear Vent Configuration with Horizontal Termination (with vertical rise)
•The termination must fall within the shaded area shown in the chart. and diffuser positions.
•Up to four elbows (45° or 90° ) may be used.
•Only one horizontal elbow may be used.
Use the indicated restrictor
0feet | 5feet |
22' (max)
20feet
15 feet
10 feet
5 feet
0 feet
0feet | 5feet |
10feet | 15feet |
Exhaust Restrictor # 5
Intake Restrictor # 2
Diffuser Position # 2
Exhaust Restrictor # 3
Intake Restrictor # 1 (stock)
Diffuser Position # 1 (stock)
10feet | 15feet |
20' (max)
22' (max)
20 feet
15 feet
10 feet
5 feet
0 feet
20' (max)
H2
This is considered a horizontal
elbow (it does not matter whether it turns right or left).
It may be a 90° or 45° elbow.
H1
Horizontal length is calculated by adding both lengths of horizontal run (Horizontal Length = H1 + H2).
This is considered a vertical elbow
© Travis Industries | 4080214 |