62 Optional Equipment (for qualified installers only)
Travis Industries 4080214 100-01182_003

Wiring Instructions

Warning: All wiring should be done by a qualified electrician and shall be in compliance with local
codes and with the current National Electric Code ANSI/NFPA 70.
Warning: Make sure the fireplace electrical circuit is disabled prior to working on electrical hookup.
Rheostat
Junction
Box
Hot
(black)
Common
(white)
Ground
(green)
Blower
Snap Disk
Fireplace
Rheostat
Fireplace
Blower
Molex
Connector
Molex
Connector
Hot
(black)
Common
(white)
Ground
(green)
Hot
(black)
Common
(white)
Ground
(green)
Heat Duct
Rheostat
Hot
(black)
Common
(white)
Ground
(green)
Hot
(black)
Common
(white)
Ground
(green)
Grounded
to Blower
Power Supply
Hot
(black)
Common
(white)
Ground
(green)
Heat Duct
Blower
Blower
Junction
Box
Optional Second Heat
Duct (same rheostat and
blower wiring as above)
Hot
(black)
Common
(white)
Ground
(green)
Fireplace

W

iring Diagram - 864 HH*, 44 DV XXL, and 36 DV

W

iring Diagram -864TRV

Hot
(black)
Common
(white)
Ground
(green)
Power Supply
Hot
(black)
Common
(white)
Ground
(green)
Rheostat
Junction Box Blower
Assembly
* 864 HH SN ?? or greater. 864
HH SN ?? or less uses wiring
similar to the 864TRV.
1 Follow the directions below to wire the blower box.
Remove the cover from the blower box.abInsert sheathed cable through the cable clamp. After the wires have been connected tighten the clamp to secure the cable.Secure the ground wire to the ground stud inside the blower box by tightening the included nut over the ground wire. Re-attach the cover removed in step "a".Attach the hot (black) and common (white) wires to the leads coming from the wires (use wire nuts).cdStandard ScrewdriverPhillips ScrewdriverGround Wire