Output Summary Screens

Output Summary Screens

The three Output Summary screens provide output-specific status of voltage, power, current, frequency, etc.

UPS Summary

~ ~

Q7

 

Q8

 

 

 

Normal

0:00 AM

Q2

Normal

Normal

Output Summary

5.40 PM

The black bars represent real-time data. Yellow triangles represent the maximum values recorded to date and blue triangles represent the minimum values recorded to date.

 

Current

 

 

 

A

 

587

 

 

 

522

 

 

 

456

 

 

 

391

 

 

 

326

 

 

 

262

 

 

 

196

 

 

 

130

 

 

 

65

 

 

 

0

13

13

13

 

 

 

 

L1

L2

L3

 

Voltage

 

 

 

V

 

607

 

 

 

540

 

 

 

472

 

 

 

405

 

 

 

337

 

 

 

270

 

 

 

202

 

 

 

135

 

 

 

67

 

 

 

0

259

264

263

 

 

 

 

L1-2 L2-3 L3-1

495

440

365

330

275

220

165

110

55

0

Total Power

kW kVA

450 453

 

Frequency

 

Hz

55.0

 

54.0

 

53.0

 

52.0

 

51.0

 

50.0

 

49.0

 

48.0

 

47.0

 

46.0

 

45.0

259

 

Page 1 of 3

These values will be reset when the output statistics are reset

Normal

 

 

Normal

 

 

Normal

 

 

Output Summary

Output Summary

5.400:00PMAM

Refresh Data

Voltage

Current

Normal

Normal

5.40 PM

 

 

L1

L2

L3

 

 

 

L1

L2

L3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Current

57.0

59.0

62.0

A

 

Active power

380

381

382

kW

 

 

200.0

 

 

 

Current high

60.0

63.0

66.0

A

Active power high

700

701

702

kW

 

 

 

Peak current

20.0

19.5

20.0

A

Apparent power

700

692

694

kVA

 

 

 

 

 

 

Peak current high

59.4

59.9

60.4

A

Apparent power high

690

682

684

kVA

 

 

 

 

THD

3.9

4.8

5.8

%

 

Power factor

0.92

0.81

0.82

 

 

 

 

 

 

 

THD high

3.8

4.7

5.7

%

 

Total active power

 

 

200

kW

 

 

 

 

 

Crest factor

2.1

2.13

2.23

 

 

Total apparent power

 

 

150

kVA

 

 

 

 

Crest factor high

2.03

2.06

2.16

 

 

 

 

 

 

 

 

 

0.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L1-2

L2-3

L3-1

 

 

Frequency

 

 

51.4

Hz

 

 

 

 

 

 

 

 

Frequency high

 

 

54.2

Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

220.5

221.0

222.0

V

 

Frequency low

 

 

45.8

Hz

 

 

 

 

Voltage high

260.0

261.0

262.0

V

Tolerance

 

 

2.0

%

 

 

 

 

 

 

Voltage low

200.0

201.0

202.0

V

 

 

 

 

 

 

 

-200.0

 

 

 

THD

 

 

4.8 %

 

Load

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THD high

2.7

3.6

4.6 %

 

 

 

 

 

 

 

 

 

 

 

 

Load

60.0

68.0

78.0

%

 

 

 

 

 

 

Voltage tolerance

 

 

5 %

 

 

 

0.0

5.0

10.0

15.0

 

 

 

Load high

58.0

66.0

76.0

%

 

 

Waveform tolerance

 

 

6 %

 

 

 

Tolerance conditions

 

 

29

 

 

Total load

 

 

142.0

%

 

 

 

 

Time (ms)

 

 

 

 

 

Total load high

 

 

250.0

%

Page 2 of 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 3 of 3