Battery Summary Screens
The three Battery Summary screens provide 
Normal
UPS Summary
0:00 AM
~ ~
Q2
Q7
Q8
Normal
Normal
Battery Summary
5.40 PM
The black bars represent 
Current
  | 
  | 
  | A  | 
  | 
  | 
  | 
200  | 
  | 
  | 
  | 
  | 
  | 
  | 
20  | 
  | 
  | 
  | 
  | 
  | 
  | 
32  | 
  | 
  | 37  | 
  | ||
  | 
  | 
  | 
  | 
  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | |
  | 
  | Batt 1  | Batt 2  | 
  | ||
  | Voltage  | 
  | 
  | V  | 
  | 
495  | 
  | 
  | 
440  | 
  | 
  | 
385  | 
  | 
  | 
330  | 
  | 
  | 
275  | 
  | 
  | 
220  | 
  | 
  | 
165  | 
  | 
  | 
110  | 
  | 
  | 
55  | 
  | 
  | 
0  | 435  | 435  | 
  | 
  | 
Batt 1 Batt 2
Runtime remaining
12 m 0 s
These values will be reset when the battery statistics are reset
Page 1 of 3
Normal
Normal
Normal
BatteryOutputSummary
2.08 PM
0:00 AM
The curve shows the battery
Normal
Normal
Normal
Battery Summary
5.40 PM
Voltage and Current
Battery 1 | 
  | 
  | 
Voltage  | 440.0  | V  | 
Voltage high  | 450.0  | V  | 
Voltage low  | 420.0  | V  | 
Current  | 57.2  | A  | 
Current high discharge  | 119.5  | A  | 
Battery 2  | 
  | 
  | 
Voltage  | 451.0  | V  | 
Voltage high  | 460.0  | V  | 
Voltage low  | 420.0  | V  | 
Current  | 51.5  | A  | 
Current high discharge  | 120.0  | A  | 
Settings | 
  | 
  | 
Min. voltage: warning  | 370  | V  | 
Min. voltage: shutdown  | 320  | V  | 
Max voltage: warning  | 460  | V  | 
Max voltage: shutdown  | 475  | V  | 
Statistics
Battery charge  | Floating  | 
  | 
Time on battery  | 0  | s  | 
Runtime remaining  | 300 m 0  | s  | 
Total time on battery  | 0  | m  | 
Total # of times on battery  | 0  | 
  | 
Charge
Boost charge  | false  | 
  | 
Auto boost charge  | false  | 
  | 
Nominal charge  | 420  | V  | 
Boost charge  | 450  | V  | 
Estimated charge time  | 65  | m  | 
Estimated charge %  | 100  | %  | 
Batt 1 charge current high  | A  | |
Batt 2 charge current high  | A  | 
Temperature
Battery  | 100  | oF  | 
Max battery  | 86  | oF  | 
Battery high  | 104  | oF  | 
Battery low  | 86  | oF  | 
Power
Battery power  | 0  | kW  | 
Battery power high discharge  | 0  | kW  | 
Battery power high charge  | 0  | kW  | 
Page 2 of 3
Refresh Data
  | 100.0  | 
  | 
  | 
Temperature  | 50.0  | 
  | 
  | 
  | 
  | 
  | |
  | 0.0  | 
  | 
  | 
  | 0.0  | 50.0  | 100.0  | 
Time (hours)
Page 3 of 3
Symmetra® MW with Internal Bypass Static Switch - User Guide -   | 9  |