Advanced Operation
ALarm
4.Click APPLY. Click OK in the confirmation window.
Alarm Inputs:
Alarm inputs are devices or switches that activate when a door, window, cabinet etc. is opened or accessed. For example, you might want to only have the camera record when someone opens a tool cabinet or when a door opens vs. recording when motion occurs around those areas. There may be people moving by those areas frequently but you are only concerned about when those areas are accessed. This saves hard drive space and makes it easier to find an event that was recorded to the hard drive.
To configure alarm inputs for devices without their own voltage you will use the +12V input supplied on the alarm block. See Alarm Inputs Configuration diagram at the right.
Note: If Alarm Input Device has its own power supply make sure:
1.Voltage rating is between 6V and 12V. Do not use the +12V connection on the Alarm Block.
2.Ground must be connected to GND in Alarm Block for device to operate properly
When an alarm is triggered, in the Live View Screen you will see a red【I】in the Channel with an alarm input warning. You may also see a【R】if you set up the channel to record when an alarm is triggered.
Alarm Inputs Conguration (for devices without voltage)
ALM2 IN | GND COM1 NO1 COM2 NO2 GND | |
1 | 3 4 |
|
Alarm Ouput: Alarm output is used to activate an external device such as a
horn or light after an alarm is triggered. To do this the DVR uses a dry contact normally open relay. This DVR has two sets of alarm outputs: COM1/NO1 and COM2/NO2. To configure alarm outputs, connect the external device to the NO (Normally Open) and COM (Common) connections on the alarm block as required by the device. See
table for Alarm Block Voltage. The maximum contact rating is 3A 24VDC. Note: ALARM MANAGE settings work the same on both outputs. Alarm inputs 1 and
2 activate alarm output COM1/NO1. Alarm inputs 3 and 4 activate alarm output COM2/NO2.
E-mail Setup:
The system can send an
1.Under EMAIL, select ON.
2.Under SSL, select OFF. NOTE: SSL deals with encryption. Only advanced users should enable this option.
3.Under SMTP PORT, enter the SMTP port of your
4.Under SMTP, enter the SMTP address of your
5.Under SEND EMAIL, enter the sender
6.Under SEND PW, enter the password of your
7.Under RECV EMAIL, enter the
8.INTERVAL: Set from 3
9.SET EMAIL CC: Add up to six Carbon Copy
10.Click APPLY. Click OK in the REMARK window.
E-mail Tip
Depending upon your settings, the system can generate a lot of
the alert
|
|
|
|
|
|
|
| NC |
|
|
|
| |
|
| COM |
|
|
|
|
| Use +12V from | |||||
| NO |
| ||||
|
| Alarm Block | ||||
| Example Device: |
| ||||
|
|
|
|
| ||
| Door Sensor |
|
|
|
| |
| ||||||
Alarm Block Voltage | ||||||
|
|
|
|
|
|
|
Max Switching Voltage | up to 24VDC |
Max Switching Current | up to3A |
E-mail Setup Screen
E-mail Carbon Copy Setup
Page 23