STEP 1.3 OPTIONS FOR INSTALLING MULTIPLE PRODUCTS

STEP 1.4 ELECTRICAL, PLUMBING & DRAINAGE INFORMATION IMPORTANT

Where the DishDrawer is in an under counter situation, i.e. built into a kitchen unit, it is recommended that bare wood surrounding the DishDrawer is sealed with an oil based paint or polyurethane to prevent possible steam damage.

GROUNDING INSTRUCTIONS IMPORTANT

If mounting the DishDrawer near the bottom of the cabinet, ensure there is adequate room underneath the supporting cabinet to tighten bolts.

PLUMBING - WATER SUPPLY IMPORTANT

Ensure the cavity sides are plumb (vertical) as this will assist with leveling the DishDrawer.

Page DS_03 IMPORTANT

Ensure the Services Hole is as close as possible to the rear corner of the cabinet. The hole can be located on either side depending on the location of the services.

Manual background IMPORTANT

On corner installations ensure that there is a gap of 2" (50mm) minimum between the adjacent cabinetry and sides of drawers.

STEP 1.3 OPTIONS FOR INSTALLING MULTIPLE PRODUCTS

STEP 1.4 ELECTRICAL, PLUMBING & DRAINAGE INFORMATION

ELECTRICAL

Care should be exercised when the appliance is installed or removed, to reduce the likelihood of damage to the power supply cord.

If the power supply cord is damaged, it must be replaced by the Manufacturer, it’s Service Agent or a similarly qualified person, in order to avoid a hazard.

The power supply receptacle for the appliance should be installed in a cabinet or on a wall adjacent to the under counter space in which the appliance is to be installed.

The power supply receptacle should be positioned between 6" and 18" (150mm and 450mm) from the cabinet opening of the DishDrawer.

GROUNDING INSTRUCTIONS

This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.

This appliance is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is installed and grounded in accordance with all local Codes & Ordinances.

PLUMBING - WATER SUPPLY

a)The water connection is to be made to a hot water supply only. Ensure the water temperature is not greater than 140°F (60°C).

b)A readily accessible shut off valve must be installed in the supply pipe.

c)The water supply pressure is to be between 4.3 p.s.i. minimum and 139 p.s.i. maximum.

d)The inlet supply hose must be connected to the water supply using a 3/8" compression type water supply fitting.

e)Ensure sealing washer supplied with connection hose is fitted.