23
Model VM08 Owner’s Manual
Doubling effect parameters (parameter type: DOUBLING)

For effect type 34 of the preceding "Effect type" table, the following three parameters can be adjusted.

1.Lch DELAY TIME Adjust the delay time of the L channel. Range: 0.1--9.9 ms (99 steps in 0.1 ms units), 10-
-99 ms (90 steps in 1 ms units), 100--200 ms (51 steps in 2 ms units)
* The ENTER key / foot switch cannot be used for tap input.
2.Rch DELAY TIME Adjust the delay time of the R channel. Range: 0.1--9.9 ms (99 steps in 0.1 ms units), 10-
-99ms (90 steps in 1 ms units), 100--200 ms (51 steps in 2 ms units)
* The ENTER key / foot switch cannot be used for tap input.
3.FILTER Adjust the tone of the delay sound. Range: L9~L1, -, H1~H9
*[-] is Filter Off
*L1~L9 = LPF (larger numbers will lower the cutoff frequency)
*H1~H9 = HPF (larger numbers will raise the cutoff frequency)
Chorus effect parameters (parameter type: CHORUS)

For effect type 35 of the preceding "Effect type" table, the following four parameters can be adjusted.

1. DEPTH Adjust the chorus depth. Range: 0--99 (100 steps in increments of 1)
2. DOUBLING TIME Adjust the time difference of the doubling effect. Range: 0--99 (100 steps in increments
of 1)
3. DOUBLING BALANCE Adjust the volume of the doubling effect. Range: 0--99 (100 steps in increments of 1)
4. FILTER Adjust the tone of the delay sound. Range: L9~L1, -, H1~H9
* [-] is Filter Off
* L1~L9 = LPF (larger numbers will lower the cutoff frequency)
* H1~H9 = HPF (larger numbers will raise the cutoff frequency)
Flanger effect parameters (parameter type: FLANGE)

For effect type 36 of the preceding "Effect type" table, the following four parameters can be adjusted.

1.RATE Adjust the speed of modulation. Range: 0.1--2.0 Hz (200 steps in 0.01 Hz units)
2.DEPTH Adjust the depth of modulation. Range: 0--99 (100 steps in increments of 1)
3. MOD DELAY Adjust the modulation delay. Range: 0--200 (201 steps in increments of 1)
4. FEEDBACK Adjust the number of modulation repeats. Range: 0--99 (100 steps in increments of 1)
Delay pitch effect parameters (parameter type: DELAY PITCH)

For effect type 38 of the preceding "Effect type" table, the following four parameters can be adjusted.

1.PITCH Adjust the amount of pitch shift. Range: -24--0--+24 (49 steps in semitone units)
*+/-12 is one octave. +/-24 is two octaves.
2.ADJUST Make fine adjustments to the amount of pitch shift. Range: -50--0--+50 (101 steps in
increments of 1)
*+50 is a semitone sharp. -50 is a semitone flat.
3.DLY TIME Adjust the delay time until the pitch-shifted sound is heard. Range: 0--500 (251 steps in
increments of 2)
* The ENTER key / foot switch can be used for tap input (refer to p.21).
4.FEEDBACK Adjust the number of delay repeats. Range: 0--99 (100 steps in increments of 1)
Mono pitch effect parameters (parameter type: MONO PITCH)

For effect type 37 of the preceding "Effect type" table, the following three parameters can be adjusted.

1.PITCH Adjust the amount of pitch shift. Range: -24--0--+24 (49 steps in semitone units)
*+/-12 is one octave. +/-24 is two octaves.
2.ADJUST Make fine adjustments to the amount of pitch shift. Range: -50--0--+50 (101 steps in
increments of 1)
*+50 is a semitone sharp. -50 is a semitone flat.
3.MODE Select the processing method. Range: 1--3 (3 steps)