Friedrich UE08, UE12, UE10 manual Procedure C Continued, Parts and Installation

Models: UE08 UE10 UE12

1 60
Download 60 pages 21.08 Kb
Page 17
Image 17
PROCEDURE C CONTINUED

PROCEDURE C CONTINUED

7

Remove the backing from the 13" shim strips

and attach them as shown below in Fig. 22.

 

 

The higher portion of shim is to be placed in

 

front of the rib on the base of wall sleeve.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1" high

 

 

 

 

 

3/4" High

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIG. 22

 

 

 

 

 

 

 

 

 

 

Shim (2EA)

6"

 

 

6"

 

 

 

 

 

FIG. 23

8 Remove the metal rear grille and replace it with the plastic rear grille to improve unit energy efficiency. The plastic grille reduces the amount of hot air discharge that recirculates through the unit.

Plastic rear grille

Steel rear grille

FIG. 24

9 Install the new unit into the wall sleeve

10 Assemble trim as described in Step 6, Procedure A.

CAUTION

Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the unit.

To prevent injury or strain, use proper lifting and carrying techniques when moving unit.

When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front and rear coils.

Make sure air conditioner does not fall during removal.

If unit does not operate after installation check, to be sure the circuit interrupter has not been tripped. Refer to the Troubleshooting guide for reset procedure.