2.Open the gas-supply valve to the fryer and check all piping, fittings, and gas connections for leaks. A soap and water solution should be used for this purpose.

DANGER

All connections must be sealed with a joint compound suitable for the gas being used and all connections must be tested with a solution of soapy water before lighting any pilots.

Never use matches, candles, or any other ignition source to check for leaks. If gas odors are detected, shut off the gas supply to the appliance at the main shut-off valve and immediately contact the local gas company or an authorized service agency for service.

3.Close the fryer drain valve and fill the frypot with water and boil-out solution to the bottom OIL- LEVEL line at the rear of the frypot. Light the fryer and perform the boil-out procedures that are described in the "Lighting Instructions" and "Boiling Out the Frypot" topics found in Chapter 3 of this manual.

DANGER

"Dry-firing"your unit will cause damage to the frypot and can cause a fire. Always ensure that melted shortening, cooking oil, or water is in the frypot before firing your unit.

4.The burner manifold pressure should be checked at this time by the local gas company or an authorized service agent. The tables below indicate the proper burner manifold pressures:

Table 5: CE Standard

Burner Manifold Gas Pressures

(Other than Belgium)

 

 

 

Model 35

Model 45

 

 

 

 

 

Gas

Pressure

Pressure

 

 

 

 

 

 

(mbar)

(mbar)

 

 

 

 

 

Natural Gas Lacq

9

7,5

 

 

 

 

 

(G20) under 20 mbar

 

 

 

 

 

 

 

 

 

 

 

 

Natural Gas Gronique

13,5

10

 

 

 

 

 

(G25) under 25 mbar

 

 

 

 

 

 

 

 

 

 

 

 

Natural Gas Gronique

13,5

10

 

 

 

 

 

(G20) under 20 mbar

 

 

 

 

 

 

 

 

 

 

 

 

Propane

22,5

20,6

 

 

 

 

 

(G31) under 37 or 50 mbar

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table6: CE Standard

Burner ManifoldGasPressures

(Belgium)

 

 

 

Model 35

Model 45

 

 

 

 

 

Gas

Pressure

Pressure

 

 

 

 

 

 

(mbar)

(mbar)

 

 

 

 

 

Natural Gas Lacq

9

7,5

 

 

 

 

 

(G20) under 20mbar

 

 

 

 

 

 

 

 

 

 

 

 

Natural Gas Gronique

9

7

 

 

 

 

 

(G25) under 25mbar

 

 

 

 

 

 

 

 

 

 

 

 

Natural Gas Gronique

9

10

 

 

 

 

 

(G20) under 20mbar

 

 

 

 

 

 

 

 

 

 

 

 

Propane

22,5

20,6

 

 

 

 

 

(G31) under 37or 50mbar

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 7: Non-CE Standard

Burner Manifold Gas Pressures

Gas

Pressure

Natural

3" W.C.

0.73 kPa

 

LP

8.25" W.C.

2.5 kPa

 

 

 

 

 

2-7