DANGER
Do not drain more than one frypot at a time into the
DANGER
NEVER attempt to clear a clogged drain valve from the front of the valve! Hot oil or shortening will rush out creating the potential for severe burns.
DO NOT hammer on the drain valve with the cleanout rod or other objects. Damage to the ball inside will result in leaks and will void the Frymaster warranty.
Install the Power Shower in the frypot to be filtered.
2. Install the Power Shower. NOTE: Verify that the Power Shower
Snap the Power Shower into position.
DANGER
DO NOT operate the filter without the Power Shower in place. Hot oil will spray out of the fryer and cause injury.
3.After the cooking oil/shortening has drained from the frypot, rotate the Oil Return handle left to the RETURN position to start the pump and begin the filtering process. There may be a slight delay before the pump activates. On fryers equipped with an optional rear- discharge system (See Section 4.6), rotating the handle to the right will discharge the oil.
Rotate the handle to the left to return oil to the frypot. Rotate to the right on fryers with optional rear- discharge to dispose of the oil.