4.Replace the Magnasol filter assembly in the filter pan.
Replace the filter assembly in the filter pan, ensuring that the fitting on the bottom of the assembly is securely seated in the port in the bottom of the pan. Sprinkle one cup of Magnasol XL filter powder evenly over the screen.
5.Replace the crumb screen, then push the filter pan back into the fryer, positioning it all the way to the back of the cabinet.
4.3Operation of the Filter
DANGER
Draining and filtering of cooking oil or shortening must be accomplished with care to avoid the possibility of a serious burn caused by careless handling. The oil to be filtered is at or near 350°F (177°C). Ensure drain handles are in their proper position before operating any switches or valves. Wear all appropriate safety equipment when draining and filtering cooking oil or shortening.
DANGER
NEVER attempt to drain cooking oil or shortening from the fryer with the burners lit! Doing so will cause irreparable damage to the frypot and may cause a flash fire. Doing so will also void the Frymaster warranty.
1.Turn the fryer power OFF. Drain ONE of the frypots into the filter pan. If necessary, use the Fryer's Friend clean- out rod to clear the drain from inside the frypot.
Rotate ONE of the drain valve handles to the left to open a drain valve.