ACCESSING THE PILOT
In
LIGHTING THE PILOT ON FRYERS WITH STANDARD HONEYWELL GAS VALVES
1.Ensure power to the unit is OFF, then turn the gas valve knob to the OFF position. Wait at least 5 minutes, then rotate the gas valve knob to the PILOT position (see Figure 1).
Lighting the Pilot
| PILOT |
ON | OFF |
| Figure 1 |
| PILOT |
ON | OFF |
| Figure 2 |
2.Push the knob in and light the pilot. (If the fryer is equipped with a piezo ignitor, repeatedly press the piezo ignitor button while depressing the gas valve knob until the pilot lights.) Continue to hold the knob in for about 60 seconds after the flame appears on the pilot. Release the knob. The pilot should remain lit.
CAUTION
If the pilot fails to remain lit, turn the gas valve knob to the OFF position and wait at least five minutes before attempting to
3.With the pilot lit, push down and slowly turn the knob to the ON position (see Figure 2 above). Once the pilot has been lit, the burner will automatically light whenever the thermostat is set above its lowest setting or the controller calls for heat.
LIGHTING THE PILOT ON FRYERS EQUIPPED WITH
1.Ensure power to the unit is OFF, then press the OFF (red) button on the gas valve (see photo below). Wait at least 5 minutes.
PILOT Button
OFF Button