45 Model Family (continued from previous page)

Model

Built-In

Controls

Filtration

(Note: Millivolt controls require no external power.)

 

PMJ*45EC

No

Electric. CM III Computer.

 

 

 

PMJ*45EBL

No

Electric. Thermostat knob on control panel with push-button basket lift control

and ON/OFF switch or Basket Lift Timer.

 

 

PMJ*45EBLC

No

Electric. CM III Computer.

 

 

 

PMJ*45EBLM

No

Electric. Thermostat knob on control panel with push-button basket lift control

plus ON/OFF and melt cycle switches.

 

 

PMJ*45EM

No

Electric. Thermostat knob on control panel with ON/OFF and melt cycle

switches.

 

 

FMP*45 or

Yes

Millivolt. Thermostat knob on control panel. (Requires external power supply

FPP*45

for filter.)

 

FMP*45E or

Yes

Electric. Thermostat knob on control panel with ON/OFF switch or Solid State

FPP*45E

Controller or Digital Controller.

 

FMP*45EC or

Yes

Electric. CM III Computer.

FPP*45EC

 

 

FMP*45EBL or

Yes

Electric. Thermostat knob on control panel with push-button basket lift control

FPP*45EBL

and ON/OFF switch or Basket Lift Timer.

 

FMP*45EBLC or

Yes

Electric. CM III Computer.

FPP*45EBLC

 

 

FMP*45EBLM or

Yes

Electric. Thermostat knob on control panel with push-button basket lift control

FPP*45EBLM

plus ON/OFF and melt cycle switches.

 

FMP*45EM or

Yes

Electric. Thermostat knob on control panel with ON/OFF and melt cycle

FPP*45EM

switches.

 

*Insert the number of fryers in the battery (e.g., a PMJ145 has one fryer, a PMJ245 or an FPP245 has two fryers; an FMP145 has one fryer and one holding station, an FMP245 has two fryers and one holding station. There is no FPP145).

† Available with pilot ignition only.

1.6Installation, Operating, and Service Personnel

Operating information for Frymaster equipment has been prepared for use by qualified and/or authorized personnel only, as defined in Section 1.7. All installation and service on Frymaster equipment must be performed by qualified, certified, licensed, and/or authorized installation or service personnel, as defined in Section 1.7.

1.7Definitions

QUALIFIED AND/OR AUTHORIZED OPERATING PERSONNEL

Qualified/authorized operating personnel are those who have carefully read the information in this manual and have familiarized themselves with the equipment functions, or who have had previous experience with the operation of the equipment covered in this manual.

QUALIFIED INSTALLATION PERSONNEL

Qualified installation personnel are individuals, firms, corporations, and/or companies which, either in person or through a representative, are engaged in and are responsible for the installation of gas- fired appliances. Qualified personnel must be experienced in such work, be familiar with all gas

1-5