GASKET | |
|
If the system is equipped with a Power Shower, drain the Power Shower completely after each use. If oil is leaking at the point where the Power Shower plugs into the frypot, verify that the
DANGER
Failure to reinstall the
5.3Annual/Periodic System Inspection
This appliance should be inspected and adjusted periodically by qualified service personnel as part of a regular kitchen maintenance program.
Frymaster recommends that a Factory Authorized Service Technician inspect this appliance at least annually as follows:
Fryer
•Inspect the cabinet inside and out, front and rear for excessive oil.
•Verify that the flue opening is not obstructed by debris or accumulations of solidified oil or shortening.
•Verify that burners and associated components (i.e. gas valves, pilot assemblies, ignitors, etc.) are in good condition and functioning properly. Inspect all gas connections for leaks and verify that all connections are properly tightened.
•Verify that the burner manifold pressure is in accordance with that specified on the appliance’s rating plate.