Frymaster J2X, J1X manual Clean Gas Valve Vent Tube, arrange this service, Preventative Maintenance

Models: J1X J2X

1 44
Download 44 pages 5.36 Kb
Page 24
Image 24
Clean Gas Valve Vent Tube

J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS

CHAPTER 5: PREVENTATIVE MAINTENANCE

5.1Fryer Preventive Maintenance Checks and Services (cont.)

c.Hold the knob and tighten the setscrew.

d.Recheck the thermometer/pyrometer reading against the temperature control knob setting the next time the burner comes on.

e.Repeat steps 4.a. through 4.d. until the thermometer/pyrometer reading and knob setting are within ± 5ºF (2°C).

If calibration is not possible, contact an authorized service agency (ASA) for service.

Clean Gas Valve Vent Tube

1.Carefully unscrew the vent tube from the valve. (NOTE: The vent tube may be straightened by hand.)

2.Pass a piece wire through the tube to remove any obstruction.

3.Remove the wire and blow through the tube to ensure it is clear.

4.Reinstall tube and bend it so that the opening is pointing downward.

SEMI-ANNUAL CHECKS AND SERVICES

Check Burner Manifold Pressure

SEMI-ANNUAL CHECKS AND SERVICES DANGER

This task should be performed by qualified service personnel only. Contact ASA to

arrange this service.

5-3

Page 24
Image 24
Frymaster J2X, J1X manual Clean Gas Valve Vent Tube, SEMI-ANNUAL CHECKS AND SERVICES Check Burner Manifold Pressure DANGER