5.2 Annual/Periodic System Inspection

J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS

CHAPTER 5: PREVENTATIVE MAINTENANCE

5.2 Annual/Periodic System Inspection

This appliance should be inspected and adjusted periodically by qualified service personnel as part of a regular kitchen maintenance program. Frymaster recommends that this appliance be inspected at least annually by a Authorized Service Agency (ASA) as follows:

Inspect the cabinet inside and out, front and rear for excessive oil build-up and/or oil migration.

Verify that the flue opening is not obstructed by debris or accumulations of solidified oil or shortening.

Verify that burners and associated components (i.e. gas valves, pilot assemblies, ignitors, etc.) are in good condition and functioning properly. Inspect all gas connections for leaks and verify that all connections are properly tightened.

Verify that the burner manifold pressure is in accordance with that specified on the appliance’s rating plate.

Verify that the temperature and high-limit probes are properly connected, tightened and functioning properly, and that probe guards are present and properly installed.

Verify that component box components (i.e. transformers, relays, interface boards, etc.) are in good condition and free from oil migration build-up and other debris. Inspect the component box wiring and verify that connections are tight and that wiring is in good condition.

Verify that all safety features (i.e. drain safety switches, reset switches, etc.) are present and functioning properly.

Verify that the frypot is in good condition and free of leaks and that the frypot insulation is in serviceable condition. Verify that the frypot tube diffusers are present and in good condition (i.e. no visible deterioration or damage).

Verify that wiring harnesses and connections are tight and in good condition.