Frymaster manual J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS, Operator Troubleshooting

Models: J1X J2X

1 44
Download 44 pages 5.36 Kb
Page 28
Image 28
Flame rolling out

J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS

CHAPTER 6: OPERATOR TROUBLESHOOTING

Flame rolling out

A. Flue obstructed.

A. Clean obstruction from flue.

from under fryer.

B. Too little make-up air in store.

B. Increase make-up air into store.

 

 

 

 

 

 

 

A. Install new burner flame

 

A. One or more burner flame

 

deflectors.

 

 

deflectors broken off.

B. Adjust pilot flame to 1 ½ inches

 

 

 

 

B. Pilot flame low – less than 1 inch

 

(38 mm).

 

 

(25.4 mm).

C. Reposition pilot hood to direct

Main burner

 

 

C. Pilot flame directed away from

 

flame toward first burner orifice.

delayed ignition

 

first orifice on main burner.

 

 

(when delay is only 2

 

 

D. Have local gas company raise

or 3 seconds).

D. Fryer incoming gas pressure too

 

incoming gas to the proper

 

 

low.

 

pressure.

 

E. Fryer incoming gas line too small.

E. Replace incoming gas line with

 

F.

One or more burner orifices

 

proper size.

 

 

 

 

 

clogged.

F.

Clean burner orifices with proper

 

 

 

 

orifice drill.

 

 

 

 

 

A. Gas valve pilot magnet weak.

A. Replace gas valve.

 

 

 

Pilot light remains

B. Pilot generator has low millivolt

B. Replace pilot generator.

lit when gas valve is

 

output.

 

 

 

 

 

 

pushed in, but goes

C. High-limit thermostat stuck open.

C. Replace high-limit.

out when released.

D. Clean/tighten high-limit wires on

 

D. Loose, dirty, or corroded high-

 

 

the gas valve.

 

 

limit wires.

 

 

 

 

 

 

 

 

 

 

6-3