Parameter Value Description
LinkSpeed_A (*1)
Auto (default)
Any connection speed of 1000, 100, or 10
Mbps is set based on negotiation with the
remote device. (This is effective only
when AutoNegotiation_A=On.)
1000 Connect at 1000Mbps.
100 Connect at 100Mbps.
10 Connect at 10Mbps.
DuplexCapabilities_A (*1)
Both (default)
Both Full-Duplex and Half-Duplex are
enabled. (This is effective only when
AutoNegotiation_A=On.)
Half Half-Duplex operation is enabled.
Full Full-Duplex operation is enabled.
FlowControl_A (*2)
Auto (default) Flow control is performed according to
the setup of the remote device.
Rem
Only flow control from the remote device
is allowed. Flow control from the local
device is not allowed.
LocSend
Only flow control from the local device is
allowed. Flow control from the remote
device is not allowed.
None Flow control is disabled.
fjgi_mtu 1500 (default) to 9000 (*3) MTU (byte) is specified.
AutoNegotiation_A
On (default)
Auto-Negotiation is enabled. The
interface will not be able to communicate
with remote device operating in fixed
mode (Auto-Negotiation disabled).
When SE0X7GD1X, SE0X7GQ1X,
SE0X7GQ2X is used in 1000Mbps mode,
use this setting.
Off Auto-Negotiation is disabled. (Forced
mode)
Role_A (*4)
Auto (default)
Master or Slave is set based on
negotiation with the remote device. (This
is effective only when
AutoNegotiation_A= On.)
Master Communication by Master.
Slave Communication by Slave.
ReceiveTicks 0 to 1000 (*3)
(default: 77)
Time to wait for an interrupt for receiving
is specified (micro seconds). (*5)
TransmitTicks 0 to 1000 (*3)
(default: 500)
Time to wait for an interrupt for
transmitting is specified (micro seconds).
(*5)
ReceiveMaxBD 1 to 500 (*3)
(default: 10)
The number of buffer descriptor to wait
for an interrupt for receiving is specified.
(*5)
- 18 -