MMB Web-UI (Web User Interface) Operations
The Reserved SB cannot be set when TPM function is used for the Home SB.
The Reserved SB cannot be set though Fixed I/O Mode is specified in the Partition.
When mounting conditions are not fulfilled, a message is displayed and Reserved SB cannot be set.
For a partition that is set to Mirror mode, if you attempt to set an SB with a DIMM configuration that does not
satisfy the Mirror mode requirements as a Reserved SB for a partition that is set to Mirror mode, a
confirmation dialog box appears. A warning message stating that Mirror Mode is cancelled while shifting to
Reserved SB is displayed in the dialog box for confirmation and whether to continue with the Reserved SB
settings is confirmed.
When several Reserved SBs are registered in one Partition, they operate as Reserved SBs in ascending
order of SB number.
TABLE 1.72 Display Items and Set Items of [Reserved SB Configuration] Window
Items
Description
#
Displays number that identifies the Partition.
Reserved: Reserved SB
Free: Free SB
Partition Name
Displays name given to Partition.
Power Status
Displays the power status of the partition
On
Standby
Mirror Mode (setting)
Displays the setting value of Mirror Mode corresponding to the Partition.
Enable: Mirror Mode is set
Disable: Mirror Mode is not set
SB
Displays the Partition to which the SB belongs.
The check box to register the SB as a Reserved SB in the Partition of the
corresponding line is
displayed in the cell which corresponds to Reserved SB or
Free SB.
TABLE 1.73 [Reserved SB Configuration] Window Buttons
Buttons
Description
Apply
If “[Apply]” button is clicked, it is defined as Reserved SB.
Cancel If “[Cancel]” button is clicked, it returns to the original state without being defined as a Reserved
SB.
(1) Menu Operation
[Partition] - [Reserved SB Configuration]
(2) Window Operations
1. The check box of Partition intended for Reserved SB is set to ON.
2. Click the [Apply] button.
[Message]
This section describes the messages to be displayed on this window.
Message Number
Message
E_00098
Failed to get the Replacement Condition
E_00100
Failed to set the Replacement Condition
E_00113
Unable to register the specified SB#%aa as a Reserved SB due to CPU mismatch
between SBs.
E_00114
The specified SB#%aa cannot be registered as a Reserved SB.
I_00223
Unable to change the specified SB(s) because the partition including the specified
SB(s) is under maintenance.
E_00419
Unable to register the specified SB#%s as a Reserved SB due to unsupported CPU
configuration.
E_00420
Unable to register the specified SB#%s as a Reserved SB because the DIMM does