MMB CLI (Command Line Interface) Operations
Privilege: Administrator
(1) Input format
set partition home <partition#> SB <SB#>
(2) Option
None
(3) Usage example
Example: When setting SB#2 as Home in Partition3
# set partition home 3 SB 2
#
(4) Message
The following table lists the messages which are displayed in this CLI.
For details of the messages, see the PRIMEQUEST 2000 Series Message Reference (C122-E178EN).
The specified partition number is invalid.
The specified SB number is invalid.
The specified SB#x is Not
present.
Unable to change the home SB while the partition is running. Please try to change the home SB after the
partition is shutdown.
Unable to execute this command on a standby MMB.
The specified parameter is invalid.
Unable to execute this command because the system is under maintenance.
Unable to execute this command because the Partition#x is under maintenance.
Succeed to set partition home command.
Failed to execute set partition home command.
Failed to execute %s command.
The specified command is not supported.(error=[%s])
2.2.26 set partition lan_device_mode
LAN Device Mode is set by the IOU unit in the specified partition.
Default value set is wol_disable.
wol_enable: Onboard LAN enabled with AC On.
wol_disable: Onboard LAN enabled with Partition On.
device_disable: Onboard LAN device disabled always.
For the partition which is already powered ON, when the settings are performed by this command, following
message is displayed and settings cannot be performed.
Unable to change the mode while the partition is running.
Please try to change the mode after the partition is shutdown.”
For the partition which is already powered OFF, when the settings are changed by this command, power
OFF/ON is not required. The value which is set is reflected instantly instead of displaying the above-
mentioned message.
Moreover, also when values which are the same as the current values are set, power off/on is not required