MMB CLI (Command Line Interface) Operations
spare: Shows Spare Mode.
Privilege: A
ll
(1) Input format
show memory_operation_mode
(2) Option
None
(3) Usage example
Example: When Memory Operation Mode of system is displayed
#show memory_operation_mode
current: normal
setting: performance
#
(4) Message
The following table lists the messages which are displayed in this CLI.
For details of the messages, see the PRIMEQUEST 2000 Series Message Reference (C122-E178EN).
The specified parameter is invalid.
Failed to execute %s command.
Failed to execute show memory_operation_mode command.
System Configuration Failed.
2.6.10 show memory_mirror_ras_mode
Displays Memory Mirror RAS Mode of the system.
mirror_keep : Sets the Mirror Keep Mode.
capacity_keep : Sets the Capacity Keep mode.
Privilege: A
ll
(1) Input format
show memory_mirror_ras_mode
(2) Option
None
(3) Usage example
Example: When Memory Mirror RAS Mode of system is displayed
#show memory_mirror_ras_mode
current: mirror_keep
setting: capacity_keep
#
(4) Message
The following table lists the messages which are displayed in this CLI.
For details of the messages, see the PRIMEQUEST 2000 Series Message Reference (C122-E178EN).
The specified parameter is invalid.