MMB Web-UI (Web User Interface) Operations
TABLE 1.74 Display Items and Set Items of [Power Management Set up] Window
Items
Description
#
Displays number (0~3) to identify the partition. However displays only the
partitions registered by SB/IOU.
Partition Name
Displays the name given to the Partition.
Power Control Status
Displays the operating state of power control status of each partition.
Normal: Normal operating state. Shows that the operating rate
suppression function for limitation of the electric power consumption is not
working.
Power Saving: Shows that the operating rate is being suppressed
Power Save Control
Valid/ invalid Power Saving function setting is executed in the partition unit.
Enable
Disable
The setting can be done only when System Power Save Control is Enable and
gray color is shown when System Power Saving Control is Disable.
Default is Enable
Power save Grace Period
Sets shutdown waiting time in Power Save Grace Period Partition unit when the
Limit threshold is exceeded.
Specified in the range of 0 ~ 99 minutes.
Shows a valid item when Power Save Control of partition is Enable and shows
gray color when Disable.
Default is 5 minutes.
Action reaching Power
Save Executes the operation setting in the partition unit after the Limit threshold
excess stand-by time.
Continue: Continues operation for the partition under operation.
Partition Power Off: Power Off is done for the partition under operation.
Partition Force Power Off: Force Power Off is done for the partition under
operation.
Displays a valid item when Power Save Control of partition is Enable and
displays gray color in case of Disable.
Default is Partition Power Off
TABLE 1.75 [Power Management Setup] Window Buttons
Buttons
Description
Apply
The setting of the Power Management Setup is changed.
Cancel
Returns to the original state without changing the setting of the Power Management Setup.
(1) Menu Operation
[Partition] - [Power Management Setup]
(2) Window Operations
1. Set the items for changing the settings of the Power Management Setup and click the [Apply] button.
Set the connection.
[Message]
This section describes the messages to be displayed on this window.
Message Number
Message
I_00013
Setting completed.
W_00426
Invalid values specified.