MMB Web-UI (Web User Interface) Operations
TABLE 1.125 Setting and display items in the [Alarm E-Mail Filtering Con dition] window
Items
Description
Severity
Sets the severity level to be displayed. Multiple options can be selected.
Error
Warning
Info
Everything is selected by default.
Partition
Sets the partitions to be displayed. Multiple options can be selected.
Everything is selected by default.
Remark
This item is not displied in case of PRIMEQUEST 2800B model.
Unit
Sets the units to be displayed.
The selected radio button is either [All] or [Specified].
All: Filtering by unit is not applied.
Specified: Filtering by unit can be set. Check the check boxes for the units to be displayed.
The default is All.
Remark
In case of PRIMEQUEST 2400E model, the Unit display is as follows:
SB SB#0, SB#1
In case of PRIMEQUEST 2800B model, the Unit display is as follows:
MMB MMB
In case of PRIMEQUEST 2800B model, PCI_Box is not displayed.
Source
Used to select the sources to be displayed.
The selected radio button is either [All] or [Specified].
All: Filtering by [Source] is not applied.
Specified: Filtering by source can be set. Check the check boxes of the sources to display.
The default is All.
Remarks
Specify both CPU and Chipset when filtering as Source with the unit of CPU.
TABLE 1.126 Buttons in the [Alarm E-Mail Filtering Condition] window
Buttons
Description
Apply
Sets the filtering conditions.
Cancel Restores the original information and does not set the specified information, such as
[Severity], [Partition], and [Unit].
(1) Menu Operation
[Network Configuration] - [Alarm E-Mail] - [Filter] button
(2) Window Operations
1. Specify the items such as [Severity], [Partition], and [Unit]. Then, click the [Apply] button.
This sets the specified filtering conditions.