MMB Web-UI (Web User Interface) Operations

FIGURE 1.2 [System Event Log] window

In the [System Event Log] Window, only the contents and not the title in the table can be scrolled. When
there are no events to be displayed, a message showing “There is no Event Logs.” is displayed instead of
the table.

TABLE 1.17 Items displayed in [System Event Log] Window

Items
Description
Severity
Displays the severity of the event and error
· Error : Severe errors like hardware error
· Warning : Not a severe error, but an error is likely in future
· Info : Shows the information like ‘Partition power ON’
Date/Time
Displays the local time when an event or error occurred.
Format: YYYY-MM-DD HH:MM:SS
Source
Displays the name of the sensor where an event or error occurred.
Unit
Displays the unit with the sensor where an event or error occurred.
For example, displays [SB#0] if an error occurs in CPU#0 of SB#0.
This unit retrieves FRU with this sensor from Entity ID of the sensor, and also retrieves
Parent Entity from Entity Association Record. It displays Board/Unit name described in
FRU Record of parent entry.
It is linked to the window (Window on which part number and serial number of each unit
can be referenced) showing detailed status of each unit.
Part Number
Displays the part number stored in system event log. If part number is not stored, “
-” is
displayed.
Event ID
Displays the ID (8 digits in hexadecimal system) for identifying contents of Event.
For details on the allocation of the Event ID, see “Chapter 2 MMB Message” of
PRIMEQUEST 2000 Series Message Reference (C122-E178EN).
Description
Displays the contents of Events and Errors.
Remarks
For the event of insertion/removal of the board, part number and serial number of board
are displayed.