MMB Web-UI (Web User Interface) Operations

FIGURE 1.11 [System Setup] Window

TABLE 1.32 Display Items and Setting Items in [System Setup] Window

Items
Description
Input Voltage
Displays input voltage.
· 100V · 200V
When information cannot be acquired, it is displayed as 200V.
Power Feed Mode
Whether power supply of PRIMEQUEST 2000 system is configured in primary
power feed mode or dual power feed mode is set.
· Single: primary power feed mode · Dual: dual power feed mode
Default setting is Single.
Power Restoration
Policy
Sets the display of the restoration action after power failure.
· Always off: Maintains the power-off status after the power restoration. · Always on: Regardless of the condition at the time of power failure, the
partition is powered on after the power restoration.
· Restore: Restores the status immediately before the power failure. If the
power was on when the power failure occurred, it restores the power-on
status of the partition. If the power was off, the partition power stays off.
· Schedule Sync: If the partition is in the operating time zone, power of partition
turns on automatically depending on the schedule operations at the time of
restoration of power.
(attention)
The schedule set with Special is applied only on the specified day.
Default setting is Restore.
Partition Power On
Delay
Sets the standby time utill power on of partition is specified as per the restoration
power policy that is set after the AC power is On (also includes restoration power).