Manual feed timeout

Manual feed timeout

This function sets the waiting time from when the host computer issues a scan command to when paper is manually put on the hopper. A manual feed timeout error occurs if this time elapses without putting paper on the hopper.

LCD display

Options

Remarks

Manual Feed Timeout

1 S to 255 S (Default: 30 S)

Unit: second

The following is an example of operation when you use this function.

1.In <<SETUP MODE>> initial screen, press

ENTER .

The <<SETUP MODE>> menu screen (Paper

Length Check) appears.

2.Press Manual Feed Timeout repeatedly until “Manual Feed Timeout” appears in the lower line of the menu screen.

3.Press ENTER .

The option select screen appears with the current setting 30 S blinking (blinking indi- cates “changeable”).

<<SETUP MODE>>

<<SETUP MODE>> Paper Length Check

<<SETUP MODE>> Manual Feed Timeout

Manual Feed Timeout

30 S

4.Press 1 S to 255 S (Default: 30 S) or Unit: second.

The displayed option changes (1 S to 255 S). The value changes in seconds.

5.When the desired value appears, press

ENTER to save the change.

The LCD returns to the <<SETUP MODE>> menu screen (Manual Feed Timeout).

Manual Feed Timeout

10 S

<<SETUP MODE>> Manual Feed Timeout

<<SETUP MODE>> Manual Feed Timeout 6-37