Setting the SCSI ID and the SCSI Terminator
The default of the SCSI ID is 5. The SCSI ID is set by using the Setup mode of the operator panel. The procedure to change the SCSI ID is as follows:
1Turn the power ON by
pressing the “I” side of the power switch (see Figure 1.1). The scanner displays “Scanner Ready” on the lower line of the LCD.
2Then press the “Next” button. The scanner displays “Mode select 1”.
3Then press the “Next”
button twice. The scanner displays “Mode select 2” meaning that the setup mode is ready.
4Then press the “Enter” button several times. The scanner displays the following:
5Press the “Next” button around times, then the scanner displays “SCSI ID” on the upper line of the LCD.
6Select the wished SCSI ID by pressing the “ ”or “ ” button, and press “Enter”. (the SCSI ID is set.)
7Press “Exit” to return to “Scanner Ready” screen if you don’t Need to change terminator.
NOTICE
If no other device is using the same SCSI ID, the scanner ID does not have to be changed.