Fujitsu M600R, M200R, M400R, M400A manual 150, External Interfaces Connection of signal lines

Models: M200 M400A GranPower7000 (GP 7000F) M400R M600 M600R M200R

1 199
Download 199 pages 16 Kb
Page 184
Image 184

CHAPTER 12 External Interfaces

Connection of signal lines

Figure 12.2 shows a configuration of signal line on connecting DCE device.

Controller/ adapter (DTE)

SD

[Send Data]

RD

[Receive Data]

RS

[Request to Send]

CS

[Clear to Send]

ER

[Equipment Ready]

DR

[Data set Ready]

CD

[Carrier Detect]

ST1

[Send Timing 1]

ST2

[Send Timing 2]

RT

[Receive Timing]

SG

[Signal Ground]

I/O Device (DTE)

Figure 12.2 Configuration of Signal Line when Connecting DCE Device(Example)

The configuration of the signal line on connecting DTE device is shown below.

Main cabinet side

I/O device side

SD

SD

RD

RD

ERER

DRDR

RSRS

CSCS

CDCD

ST1ST1

ST2

ST2

RTRT

SG SG

Note:

RS/CS flow control cannot be achieved by this wiring

Figure 12.3 Configuration of Signal Line when Connecting DTE Line(Example)

150

Page 184
Image 184
Fujitsu M600R, M200R, GranPower7000 (GP 7000F), M400R, M400A manual 150, External Interfaces Connection of signal lines