When storing the data cartridge for a long time, ensure the storage area meets the following environmental conditions and rewrite data once a year:
Temperature: 5 to 32 degree Celsius (+41 to +89.6 F)
Humidity: 20 to 60% RH
Maximum wet bulb temperature: 24 degree Celsius (+75.2 F)
If the ambient temperature or humidity changes rapidly, allow the data cartridge to adjust to the new environment before inserting it in the 8 mm tape unit.
Do not subject the data cartridge to strong shock. Do not open the data cartridge.
Do not place the data cartridge near a magnet or device generating a strong electromagnetic field.
Apply the index label to the specified location.
The data cartridge tape has a limited service life. Replace the data cartridge after using it 50 times (reference). The tape may wear out prematurely depending on the environment where it
is used.
Be sure to store data cartridges in the dedicated case.
Cleaning the magnetic head
By using the
Head cleaning cycle
Clean the magnetic head in the following cases:
A tape or hardware error occurs.
(Stains on the magnetic head may cause a hardware error.)
LEDs or console message indicates to need the head cleaning.
Both warning and ready LEDs on the 8 mm tape unit blink together.
How to use a Cleaning Cartridge
To clean the magnetic head, insert the cleaning cartridge the same way as the data cartridge. Head cleaning is completed automatically within about three minutes, then the cleaning cartridge is ejected. Do not use any other method than described in this section.
IMPORTANT
Use only Exabyte "Premium Cleaning Cartridge" or equivalents. Never use any other cleaning methods.