![](/images/new-backgrounds/1106345/106345195x1.webp)
CHAPTER 5 M400R Main Cabinet
Installation specifications
Table 5.5 Installation Specifications of M400R
Item |
| Specification |
|
|
|
|
|
Mass |
| Up to 65kg (approx.143 lb) | |
|
|
|
|
Power condition | Input voltage | Single phase | Single phase |
|
| 100 to 120 VAC | 200 to 240 VAC |
|
| ||
| Input frequency | 50/60 Hz (+2 to |
|
|
|
|
|
Maximum consumption current | 7.5 A | 3.75 A | |
|
|
| |
Leakage current (1 for each cable) | 3.5 mA or less | 3.5 mA or less | |
|
|
|
|
Ground resistance |
| 100ohm or less ( class C installation standard) | |
|
|
|
|
Temperature condition | Operating | 5 to 35 degrees Celsius (+41 to +95 F) (*1) | |
|
|
|
|
| Not operating | 0 to 50 degrees Celsius (+32 to +122F) | |
|
|
|
|
Humidity condition | Operating | 20 to 80%RH (no condensation) | |
|
|
|
|
| Not operating | 8 to 80% RH (no condensation) | |
|
|
|
|
Vibrations condition | Operating | 0.2 G |
|
|
|
|
|
| Idle | 0.4 G |
|
|
|
|
|
Noise |
| 47 db (A) (*2) |
|
|
|
|
|
Installation |
| Rack mount type (7pitches) | |
|
|
|
|
*1: If the ambient temperature exceeds 35 degrees Celsius (+95F) during operation, a warning message is displayed. Take steps to rectify the problem immediately.
*2: The indicated noise is the mean value of the measurements obtained in an anechoic chamber with less echoic influence. The actual noise measured at the installation site may be greater than the indication noise due to surrounding noise and echoes.
64