Fujitsu MAN3735, MAN3367, MAN3184 specifications LOG Select 4C, Lun Pcr

Models: MAN3735 MAN3184, MAN3367, MAN3735 SERIES DISK DRIVES MAN3367 MAN3184

1 302
Download 302 pages 19.12 Kb
Page 117
Image 117

3.1.16LOG SELECT (4C)

Bit

7

 

6

5

 

4

 

3

 

2

1

0

Byte

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

X'4C'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

LUN

 

 

0

0

 

0

PCR

SP

 

 

 

 

 

 

 

 

 

 

 

3

 

PC

0

0

0

 

0

0

0

 

 

 

 

 

 

 

 

 

 

4

0

0

0

0

0

 

0

0

0

 

 

 

 

 

 

 

 

 

 

5

0

0

0

0

0

 

0

0

0

 

 

 

 

 

 

 

 

 

 

6

0

0

0

0

0

 

0

0

0

 

 

 

 

 

 

 

 

 

7

 

 

 

 

Parameter List Length (MSB)

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

Parameter List Length (LSB)

 

 

 

 

 

 

 

 

 

 

 

 

 

9

0

 

0

0

0

0

 

0

Flag

Link

 

 

 

 

 

 

 

 

 

 

 

 

 

This command provides a means for an application client to manage statistical information maintained by the IDD about IDD. The INIT can know the types of statistical information and the current maintaining of each statistical information by using the LOG SENSE command.

A "Save Parameters (SP)" bit is one indicates that after performing the specified LOG SELECT operation the drive will save all parameters to the disc medium. A "SP" bit of zero specifies that parameters is not saved. It is not an error to set the "SP" bit to one and to set the DS bit of a log parameter to one. In this case, the parameter value for that log parameter is not saved.

The "Parameter Code Reset (PCR)" bit of one and a "Parameter list length" of zero cause all implemented parameters to be set to zero. It also clears the SMART Failure Warning and the Thermal Warning. If the "PCR" bit is one and the parameter list length is greater than zero, the command is terminated with CHECK CONDITION status(ILLEGAL REQUEST [=5] / INVALID FIELD IN CDB [=24-00]). In this case, the log paramters are not cleared. A PCR bit of zero specifies that the log parameters is not reset.

The "Page Control (PC)" bits specifies a kind and treatment content of parameters that changed by this command as shown below.

Value

Description

 

 

00b

Current threshold values

01b

Current cumulative values

10b

Default threshold values

11b

Default cumulative values

 

 