Fujitsu MAN3367, MAN3735, MAN3184 specifications Temperature page X0D, Temperature Page 0D, Code

Models: MAN3735 MAN3184, MAN3367, MAN3735 SERIES DISK DRIVES MAN3367 MAN3184

1 302
Download 302 pages 19.12 Kb
Page 252
Image 252

The Counter Value indicates the count of all non-medium errors (01/xx/xx, 02/xx/xx, 04/xx/xx, 05/xx/xx, 06/xx/xx, 07/xx/xx, 09/xx/xx and 0B/xx/xx) posted to the interface.

Implementation:

If a non-medium error is posted, it will force a save of all error log pages information.

4.2.7Temperature page (X'0D')

Byte

Bit

7

6

5

 

4

3

 

2

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

0

0

0

0

1

 

1

0

1

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

X‘00’ (Reserved)

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

Page Length (MSB)

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

Page Length (LSB)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

All of the following parameters have this header.

Page Length will be defined based on the value of Parameter Pointer. (CDB 5-6)

4.2.7.1 Temperature (Page 0D, Code 0000)

Byte

Bit

7

6

5

4

3

2

1

0

 

 

 

 

 

 

 

 

 

 

4

 

(MSB)

 

X'0000' (Parameter code)

 

 

 

5

 

 

 

 

 

 

 

 

 

(Temperature)

 

 

 

(LSB)

 

 

 

 

 

 

 

6

 

DU

DS

TSD

ETC

 

TMC

LBIN

LP

 

 

0

1

0

0

0

0

1

1

7

 

 

 

X'02' (Parameter Length)

 

 

8

 

 

 

 

X'00' (Reserved)

 

 

11

 

 

 

Temperature (degrees Celsius)

 

 

The Temperature sensed in the device at the time the LOG SENSE command is performed shall be returned in the parameter code 0000h. The one byte binary value specifies the temperature of the device in degrees Celsius. Temperatures equal to or less than zero degrees Celsius shall be indicated by a value of zero. If a valid temperature cannot be detected because of a sensor failure or other condition, the value returned shall be FFh. If EWASC (mode page 1C) is on, comparison is performed between the temperature value specified in parameter 0000h and the reference temperature specified in parameter 0001h.