6)When transfer of all the specified data is completed, the IDD reports the status and terminates the command.

Note:

In order to avoid frequent repetition of the disconnect/reconnect processing after data transfer starts on the SCSI bus, and avoid the occurrence of data overruns, it is necessary to set the buffer full ratio (see Section 2.1.2) of the MODE SELECT parameter so the difference in the data transfer rates between the INIT (SCSI bus) and the disk drive is maintained in a good balance.

Figure 2.2 shows an example of the data buffer operating state during a read operation. Details are explained in Section 2.1.2.

Sector

Disk

Amount of Data

in the Buffer

Buffer Full Ratio

SCSI Bus

DATA IN

Reconnection

Data Storage Completion Wait

Figure 2.2 Example of data buffer operation during read

(2)Write operation

After data transferred from the INIT are stored temporarily in the data buffer, they are written to the disk media. The basic write operation procedure is as shown below.

1)When the IDD receives a command and disconnects, it immediately reconnects and enters the DATA OUT phase and stores data transferred from the INIT to the data buffer (data pre-fetch). At this time, the IDD locates the position of the data block on the disk media specified by the command in parallel.

When storing of all the data specified in the command in the data buffer is completed, or if the empty space in the data buffer is all filled during data storage due to the volume of the specified data, the IDD performs disconnect processing and disconnects from the SCSI bus.

2)When locating of the target data block on the disk media is completed, the IDD writes the data in the data buffer to the disk media. If the target data block location operation is completed during the data pre-fetch processing in 1), writing of data to the disk media is performed in parallel with the data pre-fetch to the data buffer.

C141-E124-01EN

2 - 3

Page 57
Image 57
Fujitsu MAN3184, MAN3367, MAN3735 SERIES DISK DRIVES specifications Example of data buffer operation during read

MAN3735, MAN3184, MAN3367, MAN3735 SERIES DISK DRIVES, MAN3367, MAN3184 specifications

Fujitsu's MAN3184, MAN3367, and MAN3735 series disk drives represent a significant advancement in storage technology, catering to the needs of businesses seeking reliability, performance, and high capacity. These drives are designed for enterprise environments, providing exceptional data integrity and speed essential for effective data management.

The MAN3184 series is renowned for its high rotational speed of 10,000 RPM, which significantly enhances data access times. With a capacity of up to 18.4 GB, these drives are suitable for applications requiring quick read and write operations. The series employs an improved read/write head technology, which reduces latency and increases overall performance. This technology is complemented by advanced error correction mechanisms, ensuring the reliability necessary for critical data applications.

Transitioning to the MAN3367 series, these drives offer increased storage capacity and improved performance metrics. With capacities reaching up to 36.7 GB, they cater to growing data demands in modern enterprises. They also feature a 10,000 RPM spindle speed, ensuring that the drives can handle intensive workloads with ease. The MAN3367 drives include SCSI interface support, making them versatile and easy to integrate into various systems. The inclusion of intelligent caching algorithms allows for faster data retrieval, while built-in thermal management features ensure optimal performance, even under heavy usage.

The MAN3735 series takes performance up another notch, boasting higher capacities of up to 73.5 GB. These drives are particularly suited for environments that require high reliability and availability. The series utilizes a state-of-the-art SCSI Ultra160 interface, which maximizes data transfer rates, ultimately enhancing overall system efficiency. Additionally, the MAN3735 series employs advanced data protection technologies, including power loss protection and predictive failure analysis, which proactively minimizes potential downtime.

All these series of Fujitsu disk drives are built with a focus on durability and sustained performance. They are designed to operate seamlessly in high-demand environments, ensuring that organizations can rely on them for critical applications. Their compact design and energy-efficient operation make them an ideal choice for modern data centers looking to optimize space and reduce power consumption.

In summary, Fujitsu's MAN3184, MAN3367, and MAN3735 series disk drives deliver a blend of high capacity, performance, and reliability. These drives incorporate advanced technologies that address the evolving needs of enterprise storage solutions, making them a valuable asset for any organization aiming to enhance their data management capabilities.