To Select Automatic Operation

To Select Automatic Operation

Press the MASTER CONTROL button to select AUTO.

The operating mode “AUTO” will appear alone in the display. The transmit indi- cator will flash to indicate the command has been sent, and about three sec- onds later the entire display panel will reappear.

To Set the Thermostat

Press the TEMPERATURE set button.

LOW HIGH

LOW HIGH

LOW HIGH

LOW HIGH

LOW HIGH

When set to

When set to

When set to

When set to

When set to

4 °F lower

2 °F lower

“normal”

2 °F higher

4 °F higher

About three seconds later, the entire display will reappear.

NOTE: The thermostat setting should be considered a standard value, and may differ somewhat from the actual room temperature.

To Stop Operation

Press the START/STOP button.

The OPERATION indicator lamp (red) (Fig. 3 5) will go out.

About Mode Operation

AUTO:

Depending on the room temperature at the time operation begins, the operating mode will be switched automatically as shown in the accompanying table. Also, depending on the operating mode, the room temperature setting will cause the “standard” temperature to be set as shown.

Actual Room

 

Operating Mode

 

Thermostat Setting

Temperature

 

 

 

(standard setting)

88 °F or above

Cooling

82 °F

82 to 88 °F

Cooling

80 °F

78 to 82 °F

Dry

76 °F

74 to 78 °F

Dry

72 °F

Below 74 °F

Dry

68 °F

The operating mode and standard thermostat settings are selected automatically when operation begins.

When automatic operation is initiated, the fan will run at very low speed for about one minute while the unit detects and selects the proper operating mode.

Once the operating mode has been set, the mode will not change even if the room temperature changes.

If the START/STOP button is pressed to recommence operation within two hours after stopping automatic operation, the unit will begin operating from the same mode as before.

Cooling:

Use to cool your room.

Dry:

Use for gently cooling while dehumidifying your room.

You cannot heat the room during Dry mode.

During Dry mode, the unit will operate at low speed; in order to adjust room humidity, the indoor unit’s fan may stop from time to time. Also, the fan may operate at very low speed when detecting room humidity.

The fan speed cannot be changed manually when Dry mode has been selected.

Fan:

Use to circulate warm air from ceiling area throughout room when using space heaters.

Example: When set to “normal”

During Cooling/Dry mode:

Set the thermostat to a temperature setting that is lower than the current room tempera- ture. The Cooling and Dry modes will not operate if the thermostat is set higher than the actual room temperature (in Cooling mode, the fan alone will operate).

During Fan mode:

Fan operation begins when room tem- perature in the vicinity of the air condi- tioner rises above the set thermostat temperature; when the temperature drops, fan operation stops.

If the air emitted feels too cool, raise the thermostat setting.

En-10