Chapter 2 Installing the SPARC Enterprise T5140 and T5240 Servers 19
FIGURE2-4 Attachinga Mounting Bracket to the Chassis (Either Server)
b. Ensurethat the heads of the locating pins protrude though the keyed
openings in the mounting bracket. Pull the mounting bracket toward the
front of the chassis until the bracket locks into place with an audible click.
c. Verifythat all locating pins are trapped in the keyed openings and that the
correct locating pin has engaged the mounting bracket lock. See the right
side of FIGURE2-4.
3. Attachthe second mounting bracket to the left side of the chassis.
4. Determinewhich rack hole numbers to use when attaching the slide rails to
the rack posts.
If the server is two rack units high (2U), the slide rails occupy the lower half of
the 2U space.
5. Determinewhich screws you will use to mount the slide rails.
■If your rack has threaded mounting holes in the rack posts, determine
whether the threads are metric or standard. Select the appropriatescrews
from the package included in the mounting kit.