62 SPARC Enterprise T5140 and T5240 Servers Installation Guide • February 2008
To Update the Firmware
1. Ensure that the ILOM service processor network management port is
configured.
This configuration is required to access the new flashimage over the network.
See “ToConfigure the Service Processor Network Management Port” on page 47.
2. Open an SSH session to connect to the service processor.
3. Verify that the host is powered off.
If the host is not powered off, type the stop /SYS command.
4. Verify that the keyswitch_state parameter is set to normal.
5. Type the load command.
The load command updates the service processor flash image and the host
firmware. The load command requiresthe following information:
IP address of a TFTP server on the network that can access the flash image
%ssh root@xx.xxx.xx.x
...
Are you sure you want to continue connecting (yes/no)? yes
...
Password: password (nothing displayed)
Waiting for daemons to initialize...
Daemons ready
Integrated Lights Out Manager
Version 2.0.0.0
Copyright 2007 Sun Microsystems, Inc. All rights reserved.
Use is subject to license terms.
->
-> stop /SYS
-> set /SYS keyswitch_state=normal