F type

Use the optional flush mount kit OP20-29.

Name

Type

Code No.

Qty

 

 

 

 

Cosmetic panel

20-016-1051

100-251-370-10

1

 

 

 

 

Self-tapping screw

5x20

000-162-609-10

4

 

 

 

 

Hexagon-head bolt

M6x12

000-162-897-10

2

 

 

 

 

Spring washer

M6

000-158-855-10

2

 

 

 

 

1.Prepare a cutout in the mounting location whose dimensions are 183 (W) x 92

(H) mm.

2.Attach the cosmetic panel (20-016-1051) to the unit with two hex head bolts (M6x12) and two spring washers (M6).

3.Fix the unit to the mounting location with four self-tapping screws (5x20).

S type

Use the optional flush mount kit OP20-17.

.Name

Type

Code No.

Qty

 

 

 

 

Fixing plate

20-007-2401

100-183-190-10

2

 

 

 

 

Hexagon-head bolt

M6x12

000-162-897-10

2

 

 

 

 

Wing bolt

M4x30

000-804-799

4

 

 

 

 

Wing nut

M4

000-863-306

4

 

 

 

 

Spring washer

M6

000-158-855-10

2

 

 

 

 

1.Prepare a cutout in the mounting location whose dimensions are 167 (W) x 92

(H)mm.

2.Insert the unit to the cutout.

3.Attach two fixing plates (20-007-2401) to the unit with two hex bolts (M6x12) and two spring washers (M6).

4.Screw four wing bolts (M4x30) to wing nuts (M4).

5.Fasten the unit with four wing bolts and nuts.