How to attach the connector N-P-8DFB for cable 8D-FB-CV

Outer Sheath

Dimensions in millimeters.

Armor

Inner Sheath Shield

 

50

30

Cover with heat-shrink tubing and heat.

Remove outer sheath and armor by the dimensions shown left.

Expose inner sheath and shield by the dimensions shown left.

Cut off insulator and core by 10mm.

30

10

Clamp

Gasket Clamp

Nut

(reddish

 

brown)

 

Aluminum Foil

Trim shield here.

Insulator

Trim aluminum tape foil here.

Twist shield end.

Slip on clamp nut, gasket and clamp as shown left.

Fold back shield over clamp and trim.

Cut aluminum foil at four places, 90° from one another.

Fold back aluminum foil onto shield and trim.

1

5

Pin

Clamp Nut

Shell

Solder through the hole.

Expose the insulator by 1mm.

Expose the core by 5mm.

Slip the pin onto the conductor. Solder them together through the hole on the pin.

Insert the pin into the shell. Screw the clamp nut into the shell.

(Tighten by turning the clamp nut. Do not tighten by turning the shell.)

How to attach connector N-P-8DFB

2

Page 8
Image 8
Furuno FA-150 installation manual How to attach the connector N-P-8DFB for cable 8D-FB-CV, How to attach connector N-P-8DFB