Furuno FA-150 installation manual Changing Ship’s Mains Specifications, 100-115 VAC

Models: FA-150

1 58
Download 58 pages 49.3 Kb
Page 22
Image 22

2.2Changing Ship’s Mains Specifications

The AC-DC power supply PR-240 is shipped ready for connection to a 200-230 VAC ship’s mains. If the ship’s mains is 100 VAC-115 VAC, change the tap connection and terminal board connection as below. Attach label supplied as accessories to the front panel according to the ship’s mains.

Ship’s mains

Tap connection

Terminal board

 

Label

 

 

 

 

 

AC200-230V

SEL 230 V

Below (a)

200-230 VAC

2.5-2.0 A

1φ

50/60 Hz

 

 

 

 

 

AC100-115V

SEL 115 V

Below (b)

100-115 VAC

4.0-3.5 A

1φ

50/60 Hz

 

 

 

 

 

 

 

 

 

 

 

Remove screw and cover.

Cover

Front panel

(a) 200-230 VAC

1Black

2Grey

Terminal board

(b) 100-115 VAC

1Black

2Grey

 

Relay

Coil

 

 

J4

3

 

2

 

1

 

1

SEL

 

115V

 

2

Heat sink

3

SEL

4

 

5

230V

 

6

 

 

7

 

 

8

 

 

Tap connection

(Pull out to disconnect.)

Front panel

Attach appropriate label.

AC FAIL:Connect to Alarm system.

Output Setting: Normal Open Set plug to 1 & 2 pins of J4

Normal Close Set plug to 2 & 3 pins of J4 (Factory setting)

(This setting is for serial no. 022736 and after.)

AC Power Switch

(When connecting DC input, note that the DC power is supplied if this swqitch is turned off.)

Note: The DC output load must be less than 8A.

16