13.In the order shown in the figure below, pass the gland nut, flat washers (3 pcs.) and gasket onto the HV cable.

14.As shown in the figure below, fold back the armor onto the flat washer and insert it thru the other flat washer. Cut off the part of the armor that protrudes past the washer.

Flat washer

(1) (2) (3)

HV cable

Gland nut

Cut off armor that

 

protrudes past washer.

 

Gasket

15.Pass the HV cable through its cable gland and tighten gland nut.

16.Using the terminal opener, connect wiring to TB901, referring to the interconnection diagram.

CAUTION

High voltage is present at the No. 6 pin of TB901. Miswiring at this pin can damage the antenna unit.

17.Close the cover.

18.Seal the cable gland for the HV cable with putty.

Fabricating the power cable TYPCY-2.5

1.Use a ratchet or box wrench to open the port-side cover on the antenna unit.

2.Unfasten the gland nut for the power cable and remove gasket, flat washer (3 pcs.) and gland cap. (The gland cap may be discarded.)

3.Fabricate the power cable as shown below. Unravel the armor. Wrap sheath with vinyl tape to fix base of vinyl wire.

Armor

25 mm

Sheath

 

5 mm

 

Sheath

 

 

 

 

 

 

 

 

 

FV2-4

Conductor

 

 

 

 

 

 

 

 

 

 

S = 2.50 mm2

 

 

 

 

 

 

230 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

φ = 2.01 mm

Vinyl sheath Armor

SECTIONAL VIEW

 

 

 

 

 

 

 

 

 

 

How to fabricate power cable TYPCY-2.5

2-5

Page 29
Image 29
Furuno FAR-2167DS-D, FAR-2167DS-BB Fabricating the power cable TYPCY-2.5, How to fabricate power cable TYPCY-2.5