Setting method 1: DIP switch settings and gyrocompass specifications

1) Gyrocompass type

 

 

 

 

 

 

 

 

Gyrocompass

SW

SW

SW

JP1

type

1-4

1-5

1-6

 

AC synchronous

OFF

OFF

OFF

#1, #2, #3

 

 

 

 

 

DC synchronous

OFF

OFF

OFF

#2, #3, #4

 

 

 

 

 

DC step

ON

OFF

OFF

#4, #5, #6

 

 

 

 

 

Full-wave

OFF

ON

OFF

#4, #5, #6

pulsating current

 

 

 

 

 

 

 

 

 

Half-wave

ON

ON

OFF

#4, #5, #6

pulsating current

 

 

 

 

2) Frequency

 

 

 

 

 

 

 

 

Frequency

 

SW

SW

Remarks

 

1-7

1-8

 

 

 

50/60 Hz

 

OFF

OFF

AC synchronous-

 

 

 

 

pulsating current

 

 

 

 

 

400 Hz

 

ON

OFF

AC synchronous-

 

 

 

 

pulsating current

 

 

 

 

 

500 Hz

 

OFF

ON

AC synchronous-

 

 

 

 

pulsating current

 

 

 

 

 

DC

 

ON

ON

DC synchronous

 

 

 

 

DC step

3) Rotor voltage (between R1 & R2)

Rotor Voltage

SW2-1

 

JP3

20 to 45 VAC

ON

#2

30 to 70 VAC

OFF

#2

40 to 90 VAC

ON

#1

60 to 135 VAC

OFF

#1

5) Ratio

 

 

 

 

 

 

 

 

Ratio

SW1-1

SW1-2

SW1-3

360X

OFF

OFF

 

OFF

 

 

 

 

 

180X

ON

OFF

 

OFF

90X

OFF

ON

 

OFF

36X

ON

ON

 

OFF

4) Stator voltage (between S1 & S2)

 

 

 

 

 

 

 

 

 

 

 

Stator Voltage

SW2-2

 

SW2-3

JP2

20 to 45 VAC, or 20 to 60 VDC

ON

 

OFF

#2

30 to 70 VAC, or 40 to 100 VDC

OFF

 

OFF

#2

40 to 90 VAC

ON

 

OFF

#1

60 to 135 VAC

OFF

 

OFF

#1

6) Supply voltage

 

 

 

 

 

 

 

 

 

 

 

 

Stator Voltage

 

 

JP4

 

JP5

20 to 45 VAC, or 20 to 60 VDC

 

 

#2

 

#2

 

 

 

 

 

 

30 to 70 VAC, or 40 to 100 VDC

 

 

#1

 

#1

7) AD-10 format data

Select data Tx interval for ports 1 to 6 with jumper wires JP6 and JP7. The Tx interval is available in 25 msec or 200 msec. Use 25 msec for radar.

8) NMEA-0183 Tx interval and output sentence

Tx

SW

SW

Output sentence

interval

2-5

2-6

 

 

 

 

 

1 s

OFF

OFF

HDT+VHW

 

 

 

 

200 ms

ON

OFF

HDT

 

 

 

 

100 ms

OFF

ON

HDT

 

 

 

 

25 ms

ON

ON

HDT

 

 

 

 

9)NMEA-0183 Version no.

Version no. SW3-1

1.5OFF

2.0

ON

10)NMEA-0183 baud rate

Baud rate

SW3-2

4800 bps

OFF

38400 bps

ON

 

11) Power fail

 

12) Stator signal

 

detection

 

 

loss detection

 

 

Talker

SW3-3

 

Detection

 

SW2-7

 

Disable

OFF

 

Yes

 

OFF

 

Enable

ON

 

No

 

ON

(Use OFF for radar only)

 

SW2-4: factory use only

 

 

SW3-4: not used

 

After setting jumpers and DIP switches, reset the power or set SW2-8 to “CPU”.

4-6

Page 62
Image 62