Power supply unit

Refer to the illustration and table below to add (or remove) jumper connector P8 from the TX-HV Board (03P9350) and change fuse.

After completing jumper and fuse arrangements, adjust the overvoltage detection circuit, using a variable transformer.

Note: When switching from 220 VAC to 100 VAC, construct a jumper connector locally, referring to the illustration below. (VH6 connector housing is to be plugged into J8.)

Power

Fuse

Jumper connector P8

 

 

 

100 VAC

5A

Required

 

 

 

220 VAC

3A

Unnecessary

 

 

 

Unfasten four screws and remove cover for TX-HV Board.

P8/J8

6 5 4 3 2 1

Jumper connector (VH6P)

CR23

R21

TX-HV Board

Fuse

TB1

2-17