6.For Control Unit RCU-014:

a)While pressing and holding down the [HL OFF] key, press the [MENU] key five times.

b)Press the [0] key to show the INITIALIZE menu.

For Control Unit RCU-015:

See the procedure on the next page for how to show the INITIALIZE menu.

[INITIALIZE]

1BACK

2[ECHO ADJ]

3[SCANNER]

4[INSTALLATION]

5[OWN SHIP INFO]

6[ARP PRESET]

7[NETWORK]

8[OTHER]

INITIALIZE menu

7.RCU-014:Press the [2] key to open the ECHO ADJ menu.

RCU-015:Choose 2 ECHO ADJ and then push the thumbwheel.

[ECHO ADJ]

1BACK

2CABLE ATT ADJ AUTO/MANUAL 30

3HD ALIGN 000.0°

4TIMING ADJ

0

5MBS 0

6DEFAULT ANT HEIGHT 5/7.5/10/15/20/ 25/30/35/40/45/ more 50 m

7NEAR STC CURVE 2/2.5/3/3.5/4.2

8MID STC CURVE

3/4/5/6

9FAR STC CURVE 6/7/8

0RING SUPPRESSION 0

ECHO ADJ menu

8.RCU-014:Press the [3] key to choose HD ALIGN.

RCU-015:Choose 3 HD ALIGN and then push the thumbwheel.

9.RCU-014:Key in the bearing difference. The setting range is 0 to 359.9(°).

RCU-015:Spin the thumbwheel to set the bearing difference and then push the thumbwheel. The setting range is 0 to 359.9(°).

10.Confirm that the target echo is displayed at correct bearing on the screen and then push the thumbwheel.

11.RCU-014:Press the [MENU] key to finish. RCU-015:Left-click the MENU box to finish.

3-3

Page 45
Image 45
Furuno FAR-2167DS-D, FAR-2167DS-BB For Control Unit RCU-014, For Control Unit RCU-015, Initialize menu, Echo ADJ menu