Table 3-1 Maintenance schedule (con’t)

Interval

Check point

Check and measures

Remarks

 

 

 

 

3 to 6

Exposed nuts

Check for corroded or loosened

Sealing compound may be used

months

and bolts on

nuts and bolts. If necessary, clean

instead of paint. Apply a small

(for quali-

scanner unit

and repaint them thickly. Replace

amount of grease between nuts and

fied tech-

 

them if heavily corroded.

bolts for easy removal in future.

nicians

 

 

 

Scanner

Check for dirt and cracks on

Do not use plastic solvent (acetone)

only)

radiator

radiator surface. Thick dirt should

for cleaning. If you need to remove

 

 

 

be wiped off with soft cloth

ice from scanner unit, use a wooden

 

 

dampened with fresh water. if a

hammer or plastic head hammer.

 

 

crack is found, apply a slight

Crack on the unit may cause water

 

 

amount of sealing compound or

ingress, causing serious damages to

 

 

adhesive as a temporary remedy,

internal circuits.

 

 

then call for repair.

 

 

 

 

 

 

Terminal

Open scanner cover to check

When closing scanner covers in

 

strips and

terminal strip and plug

position, be careful not to catch loose

 

plugs in

connections inside. Also check

wires between covers and unit.

 

scanner unit

the rubber gasket of antenna

 

 

 

covers for deterioration.

 

 

 

 

 

6 months

CRT and

High voltage at CRT and

If CRT anode rubber cap or wire

to one

surrounding

surrounding components attract

sheath is cracked, replace it.

year

components

dust in environment which will

For service technician: Wait at

(for quali-

 

cause poor insulation. Ask a

least 3 minutes until high voltage

fied tech-

 

FURUNO representative or dealer

components (CRT and HV

nicians

 

to clean internal high-voltage

capacitors) discharge their residual

only)

 

components.

charges before accessing them.

 

 

 

 

 

Terminal

Check for loose connections.

 

 

strips,

Check contacts and plugs for

 

 

sockets, earth

proper seating, etc.

 

 

terminal

 

 

 

 

 

 

3.2 Life Expectancy of Major Parts

Table 3-2 Life expectancy of major parts

Part

Type

Code No.

Life expectancy

Radar Type

 

 

 

 

 

Magnetron

MG5240F (60 kW)

000-100-240

3,000 hours

FR-1760DS

 

 

 

 

 

Magnetron

MG5241

000-100-036

3,000 hours

FR-1710

 

 

 

 

 

Magnetron

MG5436

000-140-762

3,000 hours

FR-1725

 

 

 

 

 

3-2

Page 57