Furuno FR-1710 Setting CPA/TCPA alarm ranges, Silencing CPA/TCPA audible alarm, Lost target alarm

Models: FR-1710

1 78
Download 78 pages 34.45 Kb
Page 35
Image 35

2.Press the [2] key twice to select OFF from the ERASE field.

3.Press the [ENTER/SELECT] key followed by the [MENU] key.

Setting CPA/TCPA alarm ranges

When the predicted CPA of any target be- comes smaller than a preset CPA alarm range and its predicted TCPA less than a preset TCPA alarm limit, the EPA releases an au- dible alarm and displays the warning label COLLISION appears on the screen. In addi- tion, the EPA symbol changes to a triangle and flashes together with its vector.

Provided that this feature is used correctly, it will help prevent the risk of collision by alert- ing you to threatening targets. It is important that GAIN, A/C SEA, A/C RAIN and other radar controls are properly adjusted.

CPA/TCPA alarm ranges must be set up prop- erly taking into consideration the size, ton- nage, speed, turning performance and other characteristics of own ship.

CAUTION

CPA/TCPA Alarm

The CPA/TCPA alarm feature should never be relied upon as the sole means for detect- ing the risk of collision.

The navigator is not relieved of the respon- sibillity to keep visual lookout for avoiding collisions, whether or not the radar or other plotting aid is in use.

 

 

PLOT MENU 1

 

 

 

 

 

 

 

 

 

 

 

 

1.

MARK DISP

 

OFF

ON

 

 

 

 

2.

ERASE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.

VEC REF

 

REL

 

TRUE

 

 

 

 

 

 

 

 

 

 

 

 

4.

VEC TIME

 

30S

 

1M

3M

6M

 

 

 

 

15M

30M

 

 

 

 

 

 

 

 

 

5.

CPA SET

 

OFF

 

0.5NM 1NM 1.5NM

 

 

 

2NM

3NM

4NM

 

 

 

 

5NM

6NM

 

 

 

 

 

 

 

 

 

 

 

 

6.

TCPA SET

 

30S

 

1M

2M

3M

 

 

 

 

4M

5M

6M

12M

15M

 

 

 

 

 

 

 

 

 

7.

TRACK

 

OFF

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

8.

AUDIO ALARM

 

OFF

 

ON

 

 

 

9.

INTVAL*

 

 

1M

2M

3M

6M

 

30S

 

0.

*

 

 

 

 

 

 

 

 

* Requires ATA Board ARP-17.

Figure 1-27 PLOT menu

3.Press the [5] key for CPA SET or [6] key for TCPA set.

4.Press the [5] key or [6] key again to se- lect CPA or TCPA range desired.

5.Press the [ENTER/SELECT] key to reg- ister your selection.

6.Press the [MENU] key to close the menu.

Silencing CPA/TCPA audible alarm

Press the [AUDIO OFF] key to acknowledge and silence the CPA/TCPA aural alarm.

The flashing of the triangle plot symbol and vector remain on the screen until the dan- gerous situation is gone or you intentionally terminate tracking of the target by using the trackball.

To set the CPA/TCPA alarm ranges:

1.Press the [MENU] key.

2.Press the [7] key twice to display the PLOT menu.

Lost target alarm

When the system detects a lost target, track- ing on the target is discontinued and the tar- get symbol becomes a flashing diamond. The normal plotting symbol is restored to the tar- get when the target is manually acquired. If not reacquired the flashing diamond is auto- matically erased. To confirm a lost target, place the cursor on it and press the [CAN- CEL/CLEAR] key.

1-21

Page 35
Image 35
Furuno FR-1710 manual Setting CPA/TCPA alarm ranges, Silencing CPA/TCPA audible alarm, Lost target alarm, CPA/TCPA Alarm