3.3 Fuse Replacement

3.5 Simple Troubleshooting

Various fuses are used to protect the equip- ment from overvoltage (overcurrent) or equip- ment fault. If the fuse blows find the cause before replacing. If the fuse blows again after replacement, request service.

CAUTION

Use the proper fuse.

Use of a wrong fuse can cause fire or equipment damage.

Table 3-3 Fuses

 

Display unit

20A

 

FR-1760DS

 

 

 

Power Supply

5A, 2A

 

Unit

 

 

 

 

 

 

 

FR-1710

Display unit

20A

DC unit

FR-1725

 

10A

100VAC

 

 

5A

220VAC

 

 

 

 

3.4 Replacement of Batteries

The GYRO CONVERTER Board (option) has a battery. The battery for the RP Board pre- serves data when the power is turned off, and its life is about five years. When the battery voltage is low, NG (No Good) appears at the diagnostic test for the RP board. When this happens, contact your dealer to request re- placement of the battery.

Table 3-4 Battery replacement information

Board

Battery

Code

Name

Type

Number

 

 

 

RP Board

ER3S

000-127-759

 

 

 

GC Board

CR 1/2 8.L

000-103-769

 

 

 

This paragraph describes how to cure opera- tional problems, which can be made by ob- serving the radar picture and using operator controls and keys without opening the display unit, antenna unit or other equipment units.

The table below shows user-level troubleshooting procedures.

Table 3-5 Easy troubleshooting

Problem

Remedy

 

 

No own

Check that SHIP'S MARK ON is

ship marker

selected at the MARK/LINE menu

 

(keying sequence: [MENU], [0], [0]

 

[6], [6]). Also, own ship

 

information (length, width, etc.)

 

should have been entered in initial

 

settings. Consult a FURUNO

 

representative or dealer for

 

details.

 

 

No picture

Turn the BRILL control clockwise.

 

 

Color

Push the EBL rotary control to

appears

degauss the screen.

abnormal

 

 

 

No nav data

Turn on navigation device.

 

 

3-3