Setting method 1: by gyrocompass specifications

1) Gyrocompass type

2) Frequency

Gyrocompass

SW

SW

SW

JP1

type

1-4

1-5

1-6

 

 

 

 

 

 

AC synchronous

OFF

OFF

OFF

#1,

 

 

 

 

#2, #3

 

 

 

 

 

DC synchronous

OFF

OFF

OFF

#2,

 

 

 

 

#3, #4

 

 

 

 

 

DC step

ON

OFF

OFF

#4,

 

 

 

 

#5, #6

 

 

 

 

 

Full-wave

OFF

ON

OFF

#4,

pulsating current

 

 

 

#5, #6

 

 

 

 

 

Half-wave

ON

ON

OFF

#4,

pulsating current

 

 

 

#5, #6

 

 

 

 

 

Frequency

SW

SW

Remarks

 

1-7

1-8

 

 

 

 

 

50/60 Hz

OFF

OFF

AC synchronous

 

 

 

pulsating current

 

 

 

 

400 Hz

ON

OFF

AC synchronous

 

 

 

pulsating current

 

 

 

 

500 Hz

OFF

ON

AC synchronous

 

 

 

pulsating current

 

 

 

 

DC

ON

ON

DC synchronous

 

 

 

DC step

 

 

 

 

3)Rotor voltage (between R1 & R2)

Rotor voltage

SW 2-1

JP3

 

 

 

 

20

V to 45 VAC

ON

#2

 

 

 

 

30

V to 70 VAC

OFF

#2

 

 

 

 

40

V to 90 VAC

ON

#1

 

 

 

 

60

V to 135 VAC

OFF

#1

 

 

 

 

4)Stator voltage (between S1 and S2)

Stator voltage

SW 2-2

SW 2-3

JP2

 

 

 

 

 

 

20

V to 45

VAC, or

ON

OFF

#2

20

V to 60

VDC

 

 

 

 

 

 

 

 

 

20

V to 45

VAC, or

OFF

OFF

#2

20

V to 60

VDC

 

 

 

 

 

 

 

40 V to 90 VAC

ON

OFF

#1

 

 

 

 

60 V to 135 VAC

OFF

OFF

#1

 

 

 

 

 

 

5) Ratio

Ratio

SW1-1

SW 1-2

SW1-3

 

 

 

 

360x

OFF

OFF

OFF

 

 

 

 

180x

ON

OFF

OFF

 

 

 

 

90X

OFF

ON

OFF

 

 

 

 

36X

ON

ON

OFF

 

 

 

 

6) Supply voltage

Supply voltage

JP4

JP5

 

 

 

 

 

20

V to 45

VAC, or

#2

#2

20

V to 60

VDC

 

 

 

 

 

 

 

30

V to 135

VAC, or

#1

#1

40

V to 100

VDC

 

 

 

 

 

 

 

 

7)AD-10 format data Tx interval

Select data transmitting interval for ports 1 to 6 by jumper wires JP6 and JP7.

Note: The Tx interval is available in 25 ms or 200 ms. 25 ms is for radar; 200 ms is for all other equipment.

8)NMEA-0183 Tx interval

Tx

SW2-4

interval

 

 

 

2 seconds

ON

 

 

1 second

OFF

 

 

4-4