4.5 Alarm Kit
Necessary parts: OP03-156 (Code no. 008-500-650)
The alarm kit mainly consists of a circuit board and connection cables, and pro- vides alarm output to ship’s bridge alarm system.
Contents of Alarm Kit OP03-156
Name | Type | Code No. | Qty |
|
|
|
|
ALARM Board | 03P9262 | 1 | |
|
|
|
|
NH Connector Assy. | 1 | ||
|
|
|
|
NH Connector Assy. | 4 | ||
|
|
|
|
Cable Band | 1 | ||
|
|
|
|
Cable Tie | 3 | ||
|
|
|
|
M3X8 C2700W | 4 | ||
|
|
|
|
M4X12 C2700W | 1 | ||
|
|
|
|
Procedure
Refer to the figure below for parts locations.
1.Raise the monitor and fix it with the stay. (See page
2.Unfasten four screws to dismount the shield cover for the INT Board.
3.Fasten the ALARM Board to the display unit with four
4.Connect the NH connector
5.Fasten the cable band (supplied) with a
6.Connect an NH connector (3P, supplied) to each of J472, J473, J474 and J475 on the ALARM Board.
7.Route the NH connectors along the cables ties and pass them through the cable clamp. Fasten the shield cover removed at step 1.
8.Close the INT board cover.
9.Close the monitor.
10.Connect NH connectors to ship’s bridge alarm system: J472: ARPA guard zone; target alarm
J473: SYSTEM FAILURE (HP, BP, TRIG, VIDEO, GYRO, AZI)
J474: ARPA CPA/TCPA
J475: Spare