Napco Security Technologies WI1370 XP-400Installation Instructions, Keypad LEDs Flicker

Models: XP-400

1 28
Download 28 pages 54.33 Kb
Page 26
Image 26
8.How do I remove Keypad Sounder on Alarm?

WI1370 XP-400 Installation Instructions

8.How do I remove Keypad Sounder on Alarm?

The keypad sounder follows the Burg Output. If you need to remove the Keypad Sounder, then you must remove the Burg Output from that zone.

9.Transmitters not responding?

Open Transmitter case - Keypad should go into X-Mitter Tamper Trouble. If not:

Check Receiver Red LED should be flashing once approx. once a second. Check Receiver wiring.

Check Programming of Transmitter ID.

If Keypad does go into X-Mitter Tamper Trouble, check:

Transmitter point is programmed correctly.

Transmitter is wired correctly:

If using external switch, make sure it is wired to point 1, and point 2 is jumped out.

If using internal reed, make sure J1 is cut and both Point 1 and Point 2 terminals are jumped out.

10. Keypad LEDs Flicker.

The Keypad is not receiving a POLL from the Panel.

Check Keypad wiring.

1.The Panel is in the process of being Uploaded/Downloaded.

2.The panel is powering up. LED’s will flicker until panel has reset and is polling the keypad.

3.The connection from the control panel to the keypad is open.

11.No Keypad Entry Sounder during Entry Time?

The keypad sounder is turned off with the A9command. This command will

silence all Keypad sounds except keypad sounder on alarm. Enter A9to turn keypad sounds back on.

12. No Keypad Chime?

The keypad sounder is turned off with the A9command. This command will silence all Keypad sounds except keypad sounder on alarm. Enter A9to turn keypad sounds back on.

26

Page 26
Image 26
Napco Security Technologies WI1370 XP-400Installation Instructions, How do I remove Keypad Sounder on Alarm?