WI1370
Telephone Number 3 Programming
[50] - [59]
Programming is the same as for Telco 1. Program to split/double report to Telco 3. Refer to sections [30] through [39].
Report Codes
[60]Zone Report Codes
Report Code for Zones 1 through 4.
4/2 format - The Zone Report Code is the 1st digit of the report code sent, the second digit is the zone number of the reporting zone. For example, if zone 2 has a reportcode of 3, the report code would be 32.
3/1 format - Sends only the report Code and does not append it with the zone number.
[61]Point ID Report Codes
Point ID Report Codes are defaulted to Burglary for zones 1 through 4. Optionally, Point ID codes for zones 1 through 4 can be programmed as follows:
[1] | Reserved | [7] Gas Alarm | |
[2] | Panic | [8] | Heat Alarm |
[3] | Burglary | [9] | Reserved |
[4] | Holdup | [A] Auxiliary | |
[5] General Alarm | [B] 24 Hour | ||
[6] | Reserved |
|
|
[62]Zone Codes
follows: 1234 C2 F2 F3
[63]System Report Codes
Program a
[64]System Restore Code
The code sent when a system condition restores. The second digit of the
[65]Opening and Closing Codes
Program Opening and Closing Codes for Users 1 through 4. The second digit of the report code is the number of the user that armed or disarmed the system. For example, if the Closing Code [65] is programmed with a C, the closing code for User 2 would be C2 (4/2 format).
18